RUBY
The Modular QA Phantoms
SYSTEM QA • LINAC QA • PATIENT QA
All essential QA applications.
Comprehensive testing of the entire treatment chain.
With its unique combination of a compact, easy-to-setup base phantom, the new head phantom and highly versatile test inserts, RUBY provides you with a simple, yet comprehensive solution that helps you evaluate the entire radiotherapy treatment process.
Its scalable, modular design makes it easy for you to stay flexible and add new inserts any time. Customize RUBY to your specific needs.
Choose your insert and start testing.
The RUBY Phantoms for Your Changing Needs
RUBY Base Phantom
Perform integrated tests of the entire treatment chain from imaging to treatment planning and verification with one basic phantom. Add and expand QA capabilities when needed.
As the new modular phantom platform for radiotherapy QA, RUBY comes with a variety of exchangeable, application-specific inserts that satisfy all test requirements in a modern treatment facility.
RUBY Head Phantom
An increasing number of special stereotactic radiations are performed with couch extensions equipped with head shells. For this type of application, the RUBY system can be combined with the RUBY head phantom. The RUBY head phantom is compatible with all inserts containing CT markers that indicate the central position of the inserts. The RUBY head phantom has been successfully tested with the Brainlab mask system as well as the Encompass (QFix) mask system.


RUBY - Manufactured inhouse at our modern workshop with sub-millimeter precision:

Just pick the suitable RUBY Insert for whatever task!
Multiple metastasis applications
Perform System QA for the non-isocentric treatment of multiple metastases, with the “System QA MultiMet” insert.
Key Features
- Dedicated to the verification of non-isocentric treatment techniques with or without couch rotation
- Enables the positioning of three detectors at different positions within the insert
- Detector positions simulate the locations of three brain metastases treated simultaneous using a single isocenter
- Three bone equivalent cylinders embedded to provide contrast for positioning using kV imaging systems

System QA
Choose the “System QA” insert for comprehensive end-to-end testing with one single insert.
Key Features
- MRI visibility in all commonly used sequences (T1, T2 and FLAIR at 1.5 T) – no additional components required
- ICRU-based tissue-equivalent materials (brain, lung, bone) for verification of dose calculations at different tissue densities
- CT and MRI cavities for accurate verification of the CT/MRI image fusion algorithm of treatment planning systems
- Point dose measurements with different detector types using the same insert


LINAC QA
Perform alignment checks of the entire system, including conventional as well as 6D couches, with the “Linac QA” insert.
Key Features
- System alignment and isocenter checks with one single insert
- Daily checks of IGRT positioning accuracy as recommended in AAPM TG-179 and TG-142
- Optional tilting base for 6D couch QA
- Tissue-equivalent bone structures for enhanced visibility in kV and MV images
- Ceramic MV visible sphere at isocenter for easy Winston-Lutz testing
- Automated analysis of EPID images with optional PTW IsoCheck epid software
- Integrated with Track-it
Patient QA
Select the “Detector” insert for measurement-based dose verification of patient treatment plans.
Key Features
- Fast, accurate point dose measurements with different detector types
- “Plug and Measure” convenience using detector holders – no need to replace phantom or exchange inserts
- Dose verification of non-coplanar treatment plans


Use the “Film” insert for high-resolution dose distribution measurements in a plane using radiochromic films.
One system for all tasks - All you need for your task
LINAC QA

Perform integrated tests of the entire treatment chain from imaging to treatment planning and verification with one basic phantom. Add and expand QA capabilities when needed.
As the new modular phantom platform for radiotherapy QA, RUBY comes with a variety of exchangeable, application-specific inserts that satisfy all test requirements in a modern treatment facility.
RUBY Base Phantom


Perform alignment checks of the entire system, including conventional as well as 6D couches, with the “Linac QA” insert.
Key Features
- System alignment and isocenter checks with one single insert
- Daily checks of IGRT positioning accuracy as recommended in AAPM TG-179 and TG-142
- Optional tilting base for 6D couch QA
- Tissue-equivalent bone structures for enhanced visibility in kV and MV images
- Ceramic MV visible sphere at isocenter for easy Winston-Lutz testing
- Automated analysis of EPID images with optional PTW IsoCheck epid software
- Integrated with Track-it
"Linac QA" insert

Optional tilting base for 6D couch QA
Tilting base
Patient QA

Perform integrated tests of the entire treatment chain from imaging to treatment planning and verification with one basic phantom. Add and expand QA capabilities when needed.
As the new modular phantom platform for radiotherapy QA, RUBY comes with a variety of exchangeable, application-specific inserts that satisfy all test requirements in a modern treatment facility.
RUBY Base Phantom

"Film" insert for high-resolution dose distribution measurements in a plane using radiochromic films
"Film" insert


Select the “Detector” insert for measurement-based dose verification of patient treatment plans.
Key Features
- Fast, accurate point dose measurements with different detector types
- “Plug and Measure” convenience using detector holders – no need to replace phantom or exchange inserts
- Dose verification of non-coplanar treatment plans
"Detector" insert

Detector holder

RUBY with "Detector" insert
System QA

Perform integrated tests of the entire treatment chain from imaging to treatment planning and verification with one basic phantom. Add and expand QA capabilities when needed.
As the new modular phantom platform for radiotherapy QA, RUBY comes with a variety of exchangeable, application-specific inserts that satisfy all test requirements in a modern treatment facility.
RUBY Base Phantom


Choose the “System QA” insert for comprehensive end-to-end testing with one single insert.
Key Features
- MRI visibility in all commonly used sequences (T1, T2 and FLAIR at 1.5 T) – no additional components required
- ICRU-based tissue-equivalent materials (brain, lung, bone) for verification of dose calculations at different tissue densities
- CT and MRI cavities for accurate verification of the CT/MRI image fusion algorithm of treatment planning systems
- Point dose measurements with different detector types using the same insert
"System QA" insert


Select the “Detector” insert for measurement-based dose verification of patient treatment plans.
Key Features
- Fast, accurate point dose measurements with different detector types
- “Plug and Measure” convenience using detector holders – no need to replace phantom or exchange inserts
- Dose verification of non-coplanar treatment plans
"Detector" insert


RUBY Head Phantom
For couch extensions equipped with head shells. Compatible with all inserts containing CT markers that indicate the central position of the inserts.
"MultiMet" insert
System QA for the non-isocentric treatment of multiple metastases.
Key Features
- Dedicated to the verification of non-isocentric treatment techniques with or without couch rotation
- Enables the positioning of three detectors at different positions within the insert
- Detector positions simulate the locations of three brain metastases treated simultaneous using a single isocenter
- Three bone equivalent cylinders embedded to provide contrast for positioning using kV imaging systems
RUBY Head Phantom with "System QA MultiMet" insert

Detector holder
RUBY in Clinical Use
Explore how RUBY supports your QA needs.
Webinar "RUBY – Head phantom and MultiMet insert"
- RUBY in the clinical routine
- Head phantom for phantom positioning in head shells and patient mask systems
- Head phantom and MultiMet insert